Travel speed control
Initial pressure stage: 0.8-1.2m/min (to ensure sufficient exhaust)
Re-pressure stage: 1.5-2.0m/min (constant speed to avoid faults)
Vibration parameter matching
Frequency setting: 8000-10000rpm (adjusted according to concrete fluidity)
Amplitude control: 0.5-0.8mm (excessive amplitude causes surface slurry)
Real-time monitoring of elevation
Detect laser receiver data every 5m (allowable deviation ±3mm)
Stop immediately and cover with film in case of rain (surface water absorption rate > 3% affects strength)